Split

Split injections are ideal for samples with high concentrations, high matrix loads, or when the limits of detection do not need to be low. The reason for that is that during injection, the split vent is open and only a small part of the total flow -and therefore of the sample and matrix- is transferred into the column, avoiding column overload, and prolonging its lifetime. These liners can also be used for other applications, such as the analysis of polymers in combination with a pyrolyzer.

Standard recommendation:

227-35007-01 - for GC-2030
221-75193      - for GC-2010
221-75195      - for other models

 

Specifications & Ordering Information

P/N   Wool Description
227-35007-01
227-35007-01
Yes Standard Split Liner for GC-2030
221-75194
221-75194
No Standard Split Liner for GC-2030 and GC-2010
221-75195
221-75195
Yes Standard Split Liner for GC-2025 and GC-2014
221-41444-05
221-41444-05
No Standard Split Liner for GC-2025 and GC-2014
221-75193
221-75193
Yes Standard Split Liner for GC-2010

 

Each P/N includes 5 deactivated liners. (Standard deactivation: max. temp. 400 °C)

All liners presented here are compatible with all Shimadzu SPL-models. We recommend using the corresponding liner for each injector, as the position of the wool - or the indentations where the wool would be - has been specifically designed for each injector.

 Special deactivations

Specifications & Ordering Information

P/N   Wool/Frit Description
961-01479-05
961-01479-05
Wool

SPL Liner for basic compounds (e.g. amines);

 base deactivated
961-01479-06
961-01479-06
CarboFrit
961-01479-08
961-01479-08
Wool

 SPL Liner for reactive compounds (e.g. chlorinated pesticides);

 Siltek deactivated
961-01479-09
961-01479-09
CarboFrit

 

Each P/N includes 5 deactivated liners. Suitable for all injector models. The maximum temperatures depend on the deactivation:

-    Standard deactivation: 400  °C
-    Base deactivation: 350  °C
-    Siltek deactivation: 380 °C

 

Splitless

Splitless injections are ideal for samples with low concentrations, or when the limits of detection need to be low (e.g., trace analysis). The reason for that is that at the beginning of the injection, the split vent is closed, and all the flow is directed into the column. After a set amount of time, the vent is opened, and any remaining solvent is flushed out. 

Standard recommendation:

227-35008-01 - for standard applications
 

Specifications & Ordering Information

P/N   Wool Description
227-35008-01
227-35008-01
Yes Standard Splitless Liner; standard deactivated
221-75192
221-75192
No Splitless Liner; standard deactivated
961-01480-08
961-01480-08
Yes

Splitless Liner for reactive compounds (e.g. chlorinated pesticides);

Siltek deactivated
980-14622
980-14622
Yes

Splitless Liner for Quick-DB applications (e.g. pesticides);

Sky deactivated

 

Each P/N includes 5 deactivated liners. Suitable for all injector models. The maximum temperatures depend on the deactivation:

-    Standard deactivation: 400 °C
-    Siltek and Sky deactivation: 380 °C

 

Split / Splitless

Sometimes an instrument is used for split and splitless applications, and changing the liners accordingly is not an option. In those cases, split/splitless liners are recommended.

Standard recommendations:

227-35007-01 - for GC-2030
221-75193      - for GC-2010
221-75195      - for other models
 

Specifications & Ordering Information

P/N   Wool Description
227-35007-01
227-35007-01
Yes Standard Split/Splitless Liner for GC-2030
221-75194
221-75194
No Standard Split/Splitless Liner for GC-2030 and GC-2010
221-41444-05
221-41444-05
No Standard Split/Splitless Liner for GC-2025 and GC-2014
221-75193
221-75193
Yes Standard Split/Splitless Liner for GC-2010

 

Each P/N includes 5 deactivated liners. (Standard deactivation: max. temp. 400 °C)

All liners presented here are compatible with all Shimadzu SPL-models. However, we recommend using the corresponding liner for each injector, as the position of the wool (or the indentations where the wool would be) has been specifically designed for each injector. 

 
 
Liners with fixed wool

The wool remains in the correct position, which is critical for into wool injections.
 

Specification & Ordering Information

P/N   Wool Description
221-75188
221-75188
Yes Split/Splitless Liner with fixed wool - “onto wool”
221-75189
221-75189
Yes Split/Splitless Liner with fixed wool - “into wool”
221-75187
221-75187
Yes Tapered Split/Splitless Liner with fixed wool - "onto wool"
221-75191
221-75191
Yes Tapered Split/Splitless Liner with fixed wool - "into wool"


Each P/N includes 5 deactivated liners. Suitable for all injector models. (Standard deactivation: max. temp. 400 °C)

{"title":"T\u00e9l\u00e9chargements","description":"T\u00e9l\u00e9charger la derni\u00e8re brochure.","source":"product","key":5076,"max":30,"filter_types":["brochures"],"link_title":"Voir les autres t\u00e9l\u00e9chargements","link_url":"","pdf_links":[]} {"title":"Applications","source":"product","key":5076,"max":3,"filter_types":["applications","application_note","posters"],"link_title":"En savoir plus","link_url":false,"config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Documents techniques","source":"product","key":5076,"max":3,"filter_types":["technical","technical_reports","white_papers","primers"],"link_title":"En savoir plus","link_url":"#tbaleAnchor_technical","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Manuels","source":"product","key":5076,"max":3,"filter_types":["manuals"],"link_title":"En savoir plus","link_url":"#tbaleAnchor_manual","config_list":[],"page_links":[],"column_title":"Documents"}